SCI Abstract

search
Classification-Based Deep Learning Models for Lung Cancer and Disease Using Medical Images
Classification-Based Deep Learning Models for Lung Cancer and Disease Using Medical Images
The use of deep learning (DL) in medical image analysis has significantly improved the ability to predict lung cancer. In ...
Optimization of TOF and DOI Performance in a Multi-Resolution Detector for Brain-Dedicated PET
Optimization of TOF and DOI Performance in a Multi-Resolution Detector for Brain-Dedicated PET
Brain-dedicated positron emission tomography (PET) systems require detectors with high spatial resolution, depth-of-intera...
Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions
Performance of SiC Diodes at Very High Doses of Low-Energy Proton Beams Under FLASH Conditions
FLASH therapy has emerged as a promising radiotherapy (RT) technique, minimizing damage to healthy tissues while maintaini...
Randoms Estimation for Long Axial Field-of-View PET
Randoms Estimation for Long Axial Field-of-View PET
The high sensitivity of long axial field-of-view (AFOV) PET scanners has enabled studies over a wide range of count rates ...
ZS4D: Zero-Shot Self-Similarity-Steered Denoiser for Volumetric Photon-Counting CT
ZS4D: Zero-Shot Self-Similarity-Steered Denoiser for Volumetric Photon-Counting CT
Photon-counting computed tomography (PCCT) has emerged as a transformative imaging modality, enabling enhanced spatial res...
Cold Atmospheric Plasma for Burn Healing in Mice
Cold Atmospheric Plasma for Burn Healing in Mice
Cold atmospheric plasma (CAP) is a promising treatment for burns due to its antibacterial properties, ability to promote w...
Imaging Simulation of a Dual-Panel PET Geometry With Ultrafast TOF Detectors
Imaging Simulation of a Dual-Panel PET Geometry With Ultrafast TOF Detectors
In positron emission tomography (PET), time-of-flight (TOF) information localizes source positions along lines of response...
Enhancing the Diagnostic Accuracy of Amyloid PET: The Impact of MR-Guided PET Reconstruction
Enhancing the Diagnostic Accuracy of Amyloid PET: The Impact of MR-Guided PET Reconstruction
18F-Florbetaben (FBB) uptake in the supratentorial cortex is indicative of amyloid positivity. Due to positron emission to...
Personalized MR-Informed Diffusion Models for 3-D PET Image Reconstruction
Personalized MR-Informed Diffusion Models for 3-D PET Image Reconstruction
Recent work has shown improved lesion detectability and flexibility to reconstruction hyperparameters (e.g., scanner geome...
IEEE Transactions on Radiation and Plasma Medical Sciences Publication Information
IEEE Transactions on Radiation and Plasma Medical Sciences Publication Information
IEEE Xplore, delivering full text access to the world's highest quality technical literature in engineering and technology...
IEEE Transactions on Radiation and Plasma Medical Sciences Information for Authors
IEEE Transactions on Radiation and Plasma Medical Sciences Information for Authors
IEEE Xplore, delivering full text access to the world's highest quality technical literature in engineering and technology...
IEEE DataPort
IEEE DataPort
IEEE Xplore, delivering full text access to the world's highest quality technical literature in engineering and technology...
Affiliate Plan of the IEEE Nuclear and Plasma Sciences Society
Affiliate Plan of the IEEE Nuclear and Plasma Sciences Society
IEEE Xplore, delivering full text access to the world's highest quality technical literature in engineering and technology...
Combined XA/CT Imaging for Bone Density and Elasticity Evaluation: A Simulation Study
Combined XA/CT Imaging for Bone Density and Elasticity Evaluation: A Simulation Study
Osteoporosis is a significant public health concern that affects old adults and individuals with certain medical condition...
A Cold Atmospheric Plasma Sensor for Identification and Differentiation of Biological Tissues
A Cold Atmospheric Plasma Sensor for Identification and Differentiation of Biological Tissues
Cold atmospheric plasmas (CAPs) have emerged as the central component to plasma medicine, a relatively new research field ...
FCT-Net: Efficient Bridge Fusion Incorporating CNN-Transformer Network for Medical Image Segmentation
FCT-Net: Efficient Bridge Fusion Incorporating CNN-Transformer Network for Medical Image Segmentation
The hybrid architecture of convolutional neural networks (CNNs) and Transformers has gained popularity in medical image se...
Score-Based Generative Null-Space Shuttle for the Field-of-View of STCT Expansion
Score-Based Generative Null-Space Shuttle for the Field-of-View of STCT Expansion
Micro computed tomography (Micro-CT) is widely used across various fields for high-resolution imaging. Recently, our previ...
PROTOTWIN-PET: A Deep Learning and GPU-Based Workflow for Dose Verification in Proton Therapy With PET
PROTOTWIN-PET: A Deep Learning and GPU-Based Workflow for Dose Verification in Proton Therapy With PET
In proton therapy (PT), accurate dose delivery verification is critical for detecting treatment plan deviations. This can ...
Performance of X-Ray Photon-Counting Scintillation Detectors Under Pile-Up Conditions at 60 keV
Performance of X-Ray Photon-Counting Scintillation Detectors Under Pile-Up Conditions at 60 keV
We investigate silicon photomultiplier (SiPM)-based scintillation detectors for medical X-ray photon-counting applications...
Synthetic CT Image Generation From CBCT: A Systematic Review
Synthetic CT Image Generation From CBCT: A Systematic Review
The generation of synthetic Computed Tomography (sCT) images from cone-beam CT (CBCT) data using deep learning (DL) method...
Experimental Study of a Large Area High PDE SiPM in 0.11-μm CMOS Process for PET Applications
Experimental Study of a Large Area High PDE SiPM in 0.11-μm CMOS Process for PET Applications
Silicon photomultipliers (SiPMs) fabricated in a standard complementary metal-oxide-semiconductor (CMOS) process enable th...
High-Performance Dual-Ended SiPM Readout for TOF-PET With BGO and LYSO:Ce
High-Performance Dual-Ended SiPM Readout for TOF-PET With BGO and LYSO:Ce
Detection time performance is a key aspect for time-of-flight positron emission tomography. With recent advancement in SiP...
Beam Hardening Correction for Image-Domain Material Decomposition in Photon-Counting CT
Beam Hardening Correction for Image-Domain Material Decomposition in Photon-Counting CT
Image-domain material decomposition is widely used due to its computational efficiency and compatibility with commonly ado...