Development of a 3D-printed canine head phantom for veterinary radiotherapy

Tino R, Yeo A, Leary M, Brandt M, Kron T. A Systematic Review on 3D-Printed Imaging and Dosimetry Phantoms in Radiation Therapy, Technol. Cancer Res Treat. 2019;18:1–14. https://doi.org/10.1177/1533033819870208.

Article  Google Scholar 

Ehler ED, Barney BM, Higgins PD, Dusenbery KE. Patient specific 3D printed phantom for IMRT quality assurance. Phys Med Biol. 2014;59:5763–73. https://doi.org/10.1088/0031-9155/59/19/5763.

Article  PubMed  Google Scholar 

Solberg TD, Medin PM, Mullins J, Li S. Quality Assurance of Immobilization and Target Localization Systems for Frameless Stereotactic Cranial and Extracranial Hypofractionated Radiotherapy. Int J Radiat Oncol Biol Phys. 2008;71:S131–5. https://doi.org/10.1016/j.ijrobp.2007.05.097.

Article  PubMed  Google Scholar 

Gallo JJ, Kaufman I, Powell R, Pandya S, Somnay A, Bossenberger T, Ramirez E, Reynolds R, Solberg T, Burmeister J. Single-fraction spine SBRT end‐to‐end testing on TomoTherapy, Vero, TrueBeam, and CyberKnife treatment platforms using a novel anthropomorphic phantom. J Appl Clin Med Phys. 2015;16:170. https://doi.org/10.1120/JACMP.V16I1.5120.

Article  Google Scholar 

Saxena SNAKK, Puzhakkal N, Mathew J, K DL. Development and validation of 3D printed anthropomorphic head phantom with eccentric holes for medical LINAC quality assurance testing in stereotactic radiosurgery. Med Eng Phys. 2024;130:104217. https://doi.org/10.1016/J.MEDENGPHY.2024.104217.

Article  PubMed  Google Scholar 

Dieterich S, Cavedon C, Chuang CF, Cohen AB, Garrett JA, Lee CL, Lowenstein JR, D’Souza MF, Taylor DD, Wu X, Yu C. Report of AAPM TG 135: Quality assurance for robotic radiosurgery. Med Phys. 2011;38:2914–36. https://doi.org/10.1118/1.3579139.

Article  PubMed  Google Scholar 

Filippou V, Tsoumpas C. Recent advances on the development of phantoms using 3D printing for imaging with CT, MRI, PET, SPECT, and ultrasound. Med Phys. 2018;45:e740–60. https://doi.org/10.1002/MP.13058.

Article  PubMed  PubMed Central  Google Scholar 

Esplen N, Alyaqoub E, Bazalova-Carter M, Note T. Manufacturing of a realistic mouse phantom for dosimetry of radiobiology experiments. Med Phys. 2019;46:1030–6. https://doi.org/10.1002/MP.13310.

Article  CAS  PubMed  Google Scholar 

Bentz BZ, Chavan AV, Lin D, Tsai EHR, Webb KJ. Fabrication and application of heterogeneous printed mouse phantoms for whole animal optical imaging. Appl Opt. 2016;55:280. https://doi.org/10.1364/AO.55.000280.

Article  PubMed  PubMed Central  Google Scholar 

Tanabe Y, Iseri T, Onizuka R, Ishida T, Eto H, Nakaichi M. Improving animal-specific radiotherapy quality assurance for kilovoltage X-ray radiotherapy using a 3D printed dog skull water phantom. Open Vet J. 2023;13:427–32. https://doi.org/10.5455/OVJ.2023.V13.I4.4.

Article  PubMed  PubMed Central  Google Scholar 

Gear JI, Cummings C, Craig AJ, Divoli A, Long CDC, Tapner M, Flux GD. Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT. EJNMMI Phys. 2016;3:1–16. https://doi.org/10.1186/S40658-016-0151-6.

Article  Google Scholar 

Laidlaw J, Earl N, Shavdia N, Davis R, Mayer S, Karaman D, Richtsmeier D, Rodesch PA, Bazalova-Carter M. Design and CT imaging of casper, an anthropomorphic breathing thorax phantom. Biomed Phys Eng Express. 2023;9. https://doi.org/10.1088/2057-1976/ACB7F7.

Mayer R, Liacouras P, Thomas A, Kang M, Lin L, Simone CB. 3D printer generated thorax phantom with mobile tumor for radiation dosimetry. Rev Sci Instrum. 2015;86. https://doi.org/10.1063/1.4923294.

Esplen N, Therriault-Proulx F, Beaulieu L, Bazalova-Carter M. Preclinical dose verification using a 3D printed mouse phantom for radiobiology experiments. Med Phys. 2019;46:5294–303. https://doi.org/10.1002/MP.13790.

Article  CAS  PubMed  Google Scholar 

Steinmann A, Alvarez P, Lee H, Court L, Stafford R, Sawakuchi G, Wen Z, Fuller CD, Followill D. MRIgRT head and neck anthropomorphic QA phantom: Design, development, reproducibility, and feasibility study. Med Phys. 2020;47:604–13. https://doi.org/10.1002/MP.13951.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Cunha LT, Pereira P, Dias AG. New quality control phantom for stereotactic body radiation therapy using radiochromic EBT3 film. Physica Med. 2016;32:223. https://doi.org/10.1016/J.EJMP.2016.07.460.

Article  Google Scholar 

van Elmpt W, McDermott L, Nijsten S, Wendling M, Lambin P, Mijnheer B. A literature review of electronic portal imaging for radiotherapy dosimetry. Radiother Oncol. 2008;88:289–309. https://doi.org/10.1016/J.RADONC.2008.07.008.

Article  PubMed  Google Scholar 

Masella O, Atkinson J, Rottoo S, Weil M, Bazalova-Carter M. Initial characterization of a novel dual-robot orthovoltage radiotherapy system. Biomed Phys Eng Express. 2025;11:025057. https://doi.org/10.1088/2057-1976/ADBCB2.

Article  Google Scholar 

O’Connell J, Weil MD, Bazalova-Carter M. Non-coplanar lung SABR treatments delivered with a gantry-mounted x-ray tube. Phys Med Biol. 2024;69. https://doi.org/10.1088/1361-6560/AD111A.

Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S, Bauer C, Jennings D, Fennessy F, Sonka M, Buatti J, Aylward S, Miller JV, Pieper S, Kikinis R. 3D Slicer as an image computing platform for the Quantitative Imaging Network. Magn Reson Imaging. 2012;30:1323–41. https://doi.org/10.1016/J.MRI.2012.05.001.

Article  PubMed  PubMed Central  Google Scholar 

Reyes VAA, Howerth EW, Blas-Machado U, Platt SR, Pavarini SP, Castro LT, Church ME, Rissi DR. Glioma with cribriform plate involvement in 6 dogs. J Vet Diagn Invest. 2023;35:800–5. https://doi.org/10.1177/10406387231195291.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Stratasys SJ. 850™ Digital Anatomy™ 3D Printer, (2022).

Stratasys. VeroUltra Stratasys J55, (2021).

Stratasys A 30. (2022).

Neumann W, Pusch TP, Siegfarth M, Schad LR, Stallkamp JL. CT and MRI compatibility of flexible 3D-printed materials for soft actuators and robots used in image-guided interventions. Med Phys. 2019;46:5488–98. https://doi.org/10.1002/MP.13852.

Article  PubMed  Google Scholar 

Masella O, Murphy KJ, Bazalova-Carter M. Characterization of a new low-dose and low-energy Gafchromic film LD-V1. J Appl Clin Med Phys. 2024. https://doi.org/10.1002/ACM2.14531.

Article  PubMed  PubMed Central  Google Scholar 

Masella O, Canthal W, Braun L, Godfrey A, Winn M, Atkinson J, Clements N, Rottoo S, Chapman J, Seuster R, Braam N, Weil M, Bazalova-Carter M. Development of a motorized iris collimator for kilovoltage x-ray radiotherapy. Biomed Phys Eng Express. 2025;11:065033. https://doi.org/10.1088/2057-1976/AE183E.

Article  Google Scholar 

Ma CM, Coffey CW, DeWerd LA, Liu C, Nath R, Seltzer SM, Seuntjens JP. AAPM protocol for 40–300 kV x-ray beam dosimetry in radiotherapy and radiobiology. Med Phys. 2001;28:868–93. https://doi.org/10.1118/1.1374247.

Article  CAS  PubMed  Google Scholar 

JCGM, Evaluation of measurement data-Guide to the expression of uncertainty in measurement Évaluation des données de mesure-Guide pour l’expression de l’incertitude de mesure, (2008). www.bipm.org (accessed February 14, 2025).

Nakano M, Hill RF, Whitaker M, Kim JH, Kuncic Z. A study of surface dosimetry for breast cancer radiotherapy treatments using Gafchromic EBT2 film. J Appl Clin Med Phys. 2012;13:83–97. https://doi.org/10.1120/JACMP.V13I3.3727.

Article  Google Scholar 

Araki F. Determination of an ionization chamber response using quality index for kilovoltage x-ray beams. Radiat Phys Chem. 2021;188:109595. https://doi.org/10.1016/J.RADPHYSCHEM.2021.109595.

Article  CAS  Google Scholar 

Perl J, Shin J, Schümann J, Faddegon B, Paganetti H. TOPAS: an innovative proton Monte Carlo platform for research and clinical applications. Med Phys. 2012;39:6818–37. https://doi.org/10.1118/1.4758060.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Faddegon B, Ramos-Méndez J, Schuemann J, McNamara A, Shin J, Perl J, Paganetti H. The TOPAS tool for particle simulation, a Monte Carlo simulation tool for physics, biology and clinical research. Phys Med. 2020;72:114–21. https://doi.org/10.1016/J.EJMP.2020.03.019.

Article  PubMed  PubMed Central  Google Scholar 

Allison J, Amako K, Apostolakis J, Araujo H, Dubois PA, Asai M, Barrand G, Capra R, Chauvie S, Chytracek R, Cirrone GAP, Cooperman G, Cosmo G, Cuttone G, Daquino GG, Donszelmann M, Dressel M, Folger G, Foppiano F, Generowicz J, Grichine V, Guatelli S, Gumplinger P, Heikkinen A, Hrivnacova I, Howard A, Incerti S, Ivanchenko V, Johnson T, Jones F, Koi T, Kokoulin R, Kossov M, Kurashige H, Lara V, Larsson S, Lei F, Link O, Longo F, Maire M, Mantero A, Mascialino B, Mclaren I, Lorenzo PM, Minamimoto K, Murakami K, Nieminen P, Pandola L, Parlati S, Peralta L, Perl J, Pfeiffer A, Pia MG, Ribon A, Rodrigues P, Russo G, Sadilov S, Santin G, Sasaki T, Smith D, Starkov N, Tanaka S, Tcherniaev E, Tomé B, Trindade A, Truscott P, Urban L, Verderi M, Walkden A, Wellisch JP, Williams DC, Wright D, Yoshida H. Geant4 Developments and Applications. IEEE Trans Nucl Sci. 2006;53. https://doi.org/10.1109/TNS.2006.869826.

Allison J, Amako K, Apostolakis J, Arce P, Asai M, Aso T, Bagli E, Bagulya A, Banerjee S, Barrand G, Beck BR, Bogdanov AG, Brandt D, Brown JMC, Burkhardt H, Canal P, Cano-Ott D, Chauvie S, Cho K, Cirrone GAP, Cooperman G, Cortés-Giraldo MA, Cosmo G, Cuttone G, Depaola G, Desorgher L, Dong X, Dotti A, Elvira VD, Folger G, Francis Z, Galoyan A, Garnier L, Gayer M, Genser KL, Grichine VM, Guatelli S, Guèye P, Gumplinger P, Howard AS, Hřivnáčová I, Hwang S, Incerti S, Ivanchenko A, Ivanchenko VN, Jones FW, Jun SY, Kaitaniemi P, Karakatsanis N, Karamitrosi M, Kelsey M, Kimura A, Koi T, Kurashige H, Lechner A, Lee SB, Longo F, Maire M, Mancusi D, Mantero A, Mendoza E, Morgan B, Murakami K, Nikitina T, Pandola L, Paprocki P, Perl J, Petrović I, Pia MG, Pokorski W, Quesada JM, Raine M, Reis MA, Ribon A, Ristić A, Fira F, Romano G, Russo G, Santin T, Sasaki D, Sawkey JI, Shin II, Strakovsky A, Taborda S, Tanaka B, Tomé T, Toshito HN, Tran PR, Truscott L, Urban V, Uzhinsky JM, Verbeke M, Verderi BL, Wendt H, Wenzel DH, Wright DM, Wright T, Yamashita J, Yarba H, Yoshida. Phys Res A. 2016;835:186–225. https://doi.org/10.1016/J.NIMA.2016.06.125. Recent developments in Geant4, Nucl. Instrum. Methods.

Article  CAS 

Comments (0)

No login
gif