Hu R, Mustard CA, Burns C. Epidemiology of incident spinal fracture in a complete population. Spine. 1996;21:492–9.
Article CAS PubMed Google Scholar
Dai LY, Yao WF, Cui YM, Zhou Q. Thoracolumbar fractures in patients with multiple injuries: diagnosis and treatment-a review of 147 cases. J Trauma. 2004;56:348–55.
Dai LY, Jiang SD, Wang XY, Jiang LS. A review of the management of thoracolumbar burst fractures. Surg Neurol. 2007;67:221–31.
Gertzbein SD. Scoliosis Research Society. Multicenter spine fracture study. Spine (Phila Pa 1976). 1992;17:528–40.
Article CAS PubMed Google Scholar
Wood K, Buttermann G, Mehbod A, Garvey T, Jhanjee R, Sechriest V. Operative compared with non-operative treatment of a thoracolumbar burst fracture without neurological deficit. A prospective, randomized study. J Bone Joint Surg Am. 2003;85:773–81.
Article CAS PubMed Google Scholar
Denis F. The three-column spine and its significance in the classification of acute thoracolumbar spinal injuries. Spine. 1983;8:817–31.
Article CAS PubMed Google Scholar
Ebelke DK, Asher MA, Neff JR, Kraker DP. Survivorship analysis of VSP spine instrumentation in the treatment of thoracolumbar and lumbar burst fractures. Spine 1991; 16: S428–32.
Article CAS PubMed Google Scholar
McCormack T, Karaikovic E, Gaines RW. The load sharing classification of spine fractures. Spine. 1994;19:1741–4.
Article CAS PubMed Google Scholar
McLain RF, Sparling E, Benson DR. Early failure of short-segment pedicle instrumentation for thoracolumbar fractures. A preliminary report. J Bone Joint Surg Am. 1993;75:162–7.
Article CAS PubMed Google Scholar
Toyone T, Tanaka T, Kato D, Kaneyama R, Otsuka M. The treatment of acute thoracolumbar burst fractures with transpedicular intracorporeal hydroxyapatite grafting following indirect reduction and pedicle screw fixation: a prospective study. Spine. 2006;31:E208–14.
Aono H, Tobimatsu H, Ariga K, Kuroda M, Nagamoto Y, Takenaka S, et al. Surgical outcomes of temporary short-segment instrumentation without augmentation for thoracolumbar burst fractures. Injury. 2016;47:1337–44.
Aono H, Ishii K, Tobimatsu H, Nagamoto Y, Takenaka S, Furuya M, et al. Temporary short-segment pedicle screw fixation for thoracolumbar burst fractures. comparative study with or without vertebroplasty. Spine J. 2017;17:1113–9.
Kanna RM, Shetty AP, Rajasekaran S. Posterior fixation including the fractured vertebra for severe unstable thoracolumbar fractures. Spine J. 2015;15:256–64.
Reinhold M, Audigé L, Schnake KJ, Ballabarba C, Dai LY, Oner FV. AO spine injury classification system: a revision proposal for the thoracic and lumbar spine. Eur Spine J. 2013;22:2184–201.
Article PubMed PubMed Central Google Scholar
Guilford JP. Fundamental statistics in psychology and education. New York: McGraw Hill; 1956.
Peng Y, Zhang L, Shi T, Lv H, Zhang L, Tang P. Relationship between fracture-relevant parameteres of thoracolumbar burst fractures and the reduction of intara-canal fracture fragment. J Orthop Surg Res. 2015;27:10131.
Wang XB, Lu GH, Li J, Wang B, Lu C, Phan K. Posterior distraction and instrumentation cannnot always reduce displaced and rotated posterosuperior fracture fragments in thoracolumbar burst fracture. Clin Spine Surg. 2017;30:E317–322.
Resnick DK, Weller SJ, Benzel EC. Biomechanics of the thoracolumbar spine. Neurosurg Clin N Am. 1997;8(4):455–69.
Article CAS PubMed Google Scholar
Smith HE, Anderson DG, Vaccaro AR, Albert TJ, et al. Anatomy, Biomechanics, and Classification of Thoracolumbar Injuries. Semin Spine Surg. 2010;22(1):2–7.
Lu H, Zhang Q, Ding F, Wu Q, Liu R. Establishment and validation of a T12–L2 three-dimensional finite element model of the thoracolumbar segments. Am J Transl Res. 2022;14(3):1606–15.
PubMed PubMed Central Google Scholar
Yoganandan N, Arun MWJ, Stemper BD, Pintar FA, Maiman DJ. Biomechanics of human thoracolumbar spinal column trauma from vertical impact loading. Ann Adv Automot Med. 2013;57:155–66.
PubMed PubMed Central Google Scholar
Panjabi MM, Brand RA, White AA III. Mechanical properties of the human thoracic spine as shown by three-dimensional load-displacement curves. J Bone Joint Surg Am. 1976;58(5):642–52.
Article CAS PubMed Google Scholar
Li Y, Shen Z, Huang M, Wang X. Stepwise resection of the posterior ligamentous complex for stability of thoracolumbar compression fracture: an in vitro biomechanical investigation. Med (Baltim). 2017 Sep;96(35):e7873.
Wu CC, Jin HM, Yan YZ, Chen J, Wang K, Wang JL, et al. Biomechanical role of the thoracolumbar ligaments of the posterior ligamentous complex. World Neurosurg. 2018;112:e125–133.
Heuer F, Schmidt H, Klezl Z, Claes L, Wilke HJ. Stepwise reduction of functional spinal structures increase range of motion and change lordosis angle. J Biomech. 2007;40(2):271–80.
Aono H, Ishii K, Takenaka S, Tobimatsu H, Nagamoto Y, Horii C, et al. Risk factors for a kyphosis recurrence after short-segment temporary posterior fixation for thoracolumbar burst fractures. J Clin Neurosci. 2019;66:138–43.
Aono H, Takenaka S, Okuda S, Kikuchi T, Takeshita H. Nagata K, et al. Risk factors for. insufficient reduction after short-segment posterior fixation for thoracolumbar burst fractures: does the interval from injury onset to surgery affect 507uction of fractured vertebrae? J Orthop Surg Res. 2022;17:507.
Comments (0)