Rosier P, Schaefer W, Lose G, Goldman HB, Guralnick M, Eustice S, et al. International Continence Society Good Urodynamic Practices and terms 2016: urodynamics, uroflowmetry, cystometry, and pressure-flow study. Neurourol Urodyn. 2017;36(5):1243–60.
Rosier PFWM, Valdevenito JP, Smith P, Sinha S, Speich J, Gammie A. ICS-SUFU standard: theory, terms, and recommendations for pressure-flow studies performance, analysis, and reporting, part 1: background theory and practice. Continence. 2023;7:100710.
Rosier PFWM, Gammie A, Valdevenito JP, Speich J, Smith P, Sinha S. ICS-SUFU standard: theory, terms, and recommendations for pressure-flow studies performance, analysis, and reporting, part 2: analysis of PFS, reporting, and diagnosis. Continence. 2023;7:100709.
Gupta A, Defreitas G, Lemack GE. The reproducibility of urodynamic findings in healthy female volunteers: results of repeated studies in the same setting and after short-term follow-up. Neurourol Urodyn. 2004;23(4):311–6.
Erdem E, Akbay E, Doruk E, Cayan S, Acar D, Ulusoy E. How reliable are bladder perceptions during cystometry? Neurourol Urodyn. 2004;23(4):306–9. discussion 10.
López-Fando Lavalle L, Calleja Hermosa P, Velasco Balanza C, Jiménez Cidre M, Gutiérrez Baños JL, Viegas V, et al. Bladder capacity in women with overactive bladder syndrome: a cross-sectional study. Urology. 2023;179:44–9.
Leitner L, Walter M, Sammer U, Knupfer SC, Mehnert U, Kessler TM. Urodynamic Investigation: A Valid Tool to define normal lower urinary tract function? PLoS ONE. 2016;11(10):e0163847.
Article PubMed PubMed Central Google Scholar
Swavely NR, Speich JE, Klausner AP. Artifacts and abnormal findings may limit the use of asymptomatic volunteers as controls for studies of multi-channel urodynamics. Minerva urologica e nefrologica = The Italian journal of urology and nephrology; 2020.
Abelson B, Majerus S, Sun D, Gill BC, Versi E, Damaser MS. Ambulatory urodynamic monitoring: state of the art and future directions. Nat Rev Urol. 2019;16(5):291–301.
Article PubMed PubMed Central Google Scholar
Gammie A, Speich JE, Damaser MS, Gajewski JB, Abrams P, Rosier P, et al. What developments are needed to achieve less-invasive urodynamics? ICI-RS 2019. Neurourol Urodyn. 2020;39(Suppl 3):S36–42.
Kocher NJ, Damaser MS, Gill BC. Advances in ambulatory urodynamics. Curr Urol Rep. 2020;21(10):41.
Macnab AJ. The evolution of near infrared spectroscopy in urology. Biomedical Spectrosc Imaging. 2014;3:311–44.
Kamran MA, Mannan MMN, Jeong MY. Cortical Signal Analysis and advances in Functional Near-Infrared Spectroscopy Signal: a review. Front Hum Neurosci. 2016;10(261).
Koven A, Herschorn S. NIRS: past, Present, and Future in Functional Urology. Curr Bladder Dysfunct Rep. 2022;17(4):241–9.
Article PubMed PubMed Central Google Scholar
Tu KJ, Lam JH, Kim S. A narrative review on the use of near-infrared spectroscopy to monitor bladder volume and in vitro validation approaches. Transl Androl Urol. 2023;12(11):1732–9.
Article PubMed PubMed Central Google Scholar
Stothers L, Shadgan B, Macnab A. Urological applications of near infrared spectroscopy. Can J Urol. 2008;15(6):4399–409.
Haylen BT, de Ridder D, Freeman RM, Swift SE, Berghmans B, Lee J, et al. An International Urogynecological Association (IUGA)/International Continence Society (ICS) joint report on the terminology for female pelvic floor dysfunction. Neurourol Urodyn. 2010;29(1):4–20.
Vijaya G, Digesu GA, Derpapas A, Panayi DC, Fernando R, Khullar V. Changes in detrusor muscle oxygenation during detrusor overactivity contractions. Eur J Obstet Gynecol Reprod Biol. 2012;163(1):104–7.
Farag FF, Martens FM, D’Hauwers KW, Feitz WF, Heesakkers JP. Near-infrared spectroscopy: a novel, noninvasive, diagnostic method for detrusor overactivity in patients with overactive bladder symptoms–a preliminary and experimental study. Eur Urol. 2011;59(5):757–62.
Mastoroudes H, Giarenis I, Vella M, Srikrishna S, Robinson D, Cardozo L, et al. Use of near infrared spectroscopy as an alternative to videourodynamics to detect detrusor overactivity in women with the overactive bladder syndrome. Urology. 2012;80(3):547–50.
Chapple CR, Osman NI, Birder L, Dmochowski R, Drake MJ, van Koeveringe G, et al. Terminology report from the International Continence Society (ICS) Working Group on underactive bladder (UAB). Neurourol Urodyn. 2018;37(8):2928–31.
R L, A. C PT, P F, C V et al. F. E,. Bladder NIRS: A non-invasive method functional to distinguish between detrusor underactivity (DU) and Bladder Outlet Obstruction (BOO) in men with LUTS. UROLUTS: EAU Edu Platform on functional urology [Internet]. 2021. Available from: https://uroluts.uroweb.org/publication/bladder-nirs-a-non-invasive-method-functional-to-distinguish-between-detrusor-underactivity-du-and-bladder-outlet-obstruction-boo-in-men-with-luts/
Macnab AJ, Stothers L. Near-infrared spectroscopy: validation of bladder-outlet obstruction assessment using non-invasive parameters. Can J Urol. 2008;15(5):4241–8.
Koeck I, Burkhard FC, Monastyrskaya K. Activation of common signaling pathways during remodeling of the heart and the bladder. Biochem Pharmacol. 2016;102:7–19.
Article CAS PubMed Google Scholar
Guevara R, Stothers L, Macnab AJ. Mathematical modeling methodology for generation of a diagnostic algorithm using near-infrared data. Spectrosc Spectrosc. 2011;25:1–11.
Hanno P, Dmochowski R. Status of international consensus on interstitial cystitis/bladder pain syndrome/painful bladder syndrome: 2008 snapshot. Neurourol Urodyn. 2009;28(4):274–86.
Lynes WL, Flynn SD, Shortliffe LD, Stamey TA. The histology of interstitial cystitis. Am J Surg Pathol. 1990;14(10):969–76.
Article CAS PubMed Google Scholar
Macnab BSLS. Noninvasive diagnosis of bladder dysfunction in patients with interstitial cystitis/painful bladder syndrome using near infrared spectroscopy. J Urol [Internet]. 2012;187(4):e935.
Afshar K, Shadgan B, Stothers L, Macnab A. Near infrared spectroscopy (NIRS) and altered detrusor oxygen consumption in non-neurogenic lower urinary tract dysfunction in children. J Urol [Internet]. 2010; 183(4):e62910.10(4).
Huppert TJ, Diamond SG, Franceschini MA, Boas DA. HomER: a review of time-series analysis methods for near-infrared spectroscopy of the brain. Appl Opt. 2009;48(10):D280–98.
Article PubMed PubMed Central Google Scholar
Ghatas MP, Burkett LS, Grob G, Daniels PT, Stothers L, Query HE, et al. A stepwise approach for functional near infrared spectroscopy measurement during natural bladder filling. Transl Androl Urol. 2023;12(10):1477–86.
Article PubMed PubMed Central Google Scholar
Molavi B, Shadgan B, Macnab AJ, Dumont GA. Noninvasive optical monitoring of bladder filling to Capacity using a Wireless Near Infrared Spectroscopy device. IEEE Trans Biomed Circuits Syst. 2014;8(3):325–33.
Fong D, Alcantar AV, Gupta P, Ghiasi EK S, editors. Non-invasive bladder volume sensing for neurogenic bladder dysfunction management. IEEE 15th International Conference on Wearable and Implantable Body Sensor Networks; 2018; Las Vegas, NV, USA.
Lee K, Lee MH, Kang D, Kim S, Chang JH, Oh SJ, Hwang JY. Intelligent bladder volume monitoring for Wearable Ultrasound devices: enhancing Accuracy through Deep Learning-based coarse-to-fine shape estimation. IEEE Trans Ultrason Ferroelectr Freq Control. 2024;71(7):775–85.
Toymus AT, Yener UC, Bardakci E, Temel ÖD, Koseoglu E, Akcoren D, et al. An integrated and flexible ultrasonic device for continuous bladder volume monitoring. Nat Commun. 2024;15(1):7216.
Article CAS PubMed PubMed Central Google Scholar
Vinod NN, Nagle AS, Naimi HA, Kolli H, Sheen D, Nandanan N, et al. Bladder volume correction factors measured with 3D ultrasound and BladderScan. Can J Urol. 2019;26(4):9829–34.
PubMed PubMed Central Google Scholar
Zhao L, Liao L, Gao L, Gao Y, Chen G, Cong H, et al. Effects of bladder shape on accuracy of measurement of bladder volume using portable ultrasound scanner and development of correction method. Neurourol Urodyn. 2019;38(2):653–9.
Cho H, Song I, Jang J, Yoo Y. A Lightweight Deep Learning Network on a system-on-chip for Wearable Ultrasound bladder volume Measurement systems: preliminary study. Bioeng (Basel). 2023;10(5).
Peng Z, Shan H, Yang X, Li S, Tang D, Cao Y, et al. Weakly supervised learning-based 3D bladder reconstruction from 2D ultrasound images for bladder volume measurement. Med Phys. 2024;51(2):1277–88.
Article CAS PubMed Google Scholar
Sheen D, Kolli H, Nagle AS, Cullingsworth Z, Vinod NN, Naimi HA, et al. Validation of a real-time bladder sensation meter during oral hydration in healthy adults: repeatability and effects of fil
Comments (0)