George EI, Brand TC, LaPorta A, Marescaux J, Satava RM. Origins of robotic surgery: from skepticism to standard of care. JSLS J Soc Laparoendosc Surg. 2018;22(4): e2018.00039.
Paul HA, Bargar WL, Mittlestadt B, Musits B, Taylor RH, Kazanzides P, Zuhars J, Williamson B, Hanson W. Development of a surgical robot for cementless total hip arthroplasty. Clin Orthop Relat Res. 1992;285:57–66.
Spencer EH. The ROBODOC clinical trial: a robotic assistant for total hip arthroplasty. Orthop Nurs. 1996;15(1):9–14.
Chen AF, Kazarian GS, Jessop GW, Makhdom A. Robotic technology in orthopaedic surgery. J Bone Joint Surg. 2018;100(22):1984–92.
Guo DH, Li XM, Ma SQ, Zhao YC, Qi C, Xue Y. Total hip arthroplasty with robotic arm assistance for precise cup positioning: a case-control study. Orthop Surg. 2022;14(7):1498–505.
Zhang S, Liu YB, Ma MY, Cao Z, Kong XP, Chai W. Revision total hip arthroplasty with severe acetabular defect: a preliminary exploration and attempt of robotic-assisted technology. Orthop Surg. 2022;14(8):1912–7.
Wu XD, Zhou Y, Shao H, Yang D, Guo SJ, Huang W. Robotic-assisted revision total joint arthroplasty: a state-of-the-art scoping review. EFORT Open Rev. 2023;8(1):18–25.
Holzgrefe RE, Hao KA, Panther EJ, Schoch BS, Roche CP, King JJ, Wright JO, Wright TW. Early clinical outcomes following navigation-assisted baseplate fixation in reverse total shoulder arthroplasty: a matched cohort study. J Shoulder Elb Surg. 2023;32(2):302–9.
Twomey-Kozak J, Hurley E, Levin J, Anakwenze O, Klifto C. Technological innovations in shoulder replacement: current concepts and the future of robotics in total shoulder arthroplasty. J Shoulder Elb Surg. 2023. https://doi.org/10.1016/j.jse.2023.04.022.
Nascimento LGP, Ikemoto RY, Wright T. Navigation in shoulder arthroplasty surgery. Rev Bras Ortop (Sao Paulo). 2022;57(4):540–5.
Leafblad N, Asghar E, Tashjian RZ. Innovations in shoulder arthroplasty. J Clin Med. 2022;11(10):2799.
Kurmis AP, Ianunzio JR. Artificial intelligence in orthopedic surgery: evolution, current state and future directions. Arthroplasty. 2022;4(1):9.
Cabarcas BC, Cvetanovich GL, Gowd AK, Liu JN, Manderle BJ, Verma NN. Accuracy of patient-specific instrumentation in shoulder arthroplasty: a systematic review and meta-analysis. JSES Open Access. 2019;3(3):117–29.
Darwood A, Hurst SA, Villatte G, Tatti F, El Daou H, Reilly P, Baena FR, Majed A, Emery R. Novel robotic technology for the rapid intraoperative manufacture of patient-specific instrumentation allowing for improved glenoid component accuracy in shoulder arthroplasty: a cadaveric study. J Shoulder Elb Surg. 2022;31(3):561–70.
Dekker A, Tambe AA. Navigation in shoulder arthroplasty. J Arthrosc Joint Surg. 2021;8(1):35–43.
Facca S, Hendriks S, Mantovani G, Selber JC, Liverneaux P. Robot-assisted surgery of the shoulder girdle and brachial plexus. Semin Plast Surg. 2014;28(1):39–44.
Garcia JC Jr, Cordeiro EF, de Paiva Raffaelli M, Mello MB, Kozonara ME, da Motta Cardoso Á Jr, Torres MC. Robotic transfer of the latissimus dorsi. Arthrosc Techn. 2020;9(6):e769–73.
Garcia JC Jr, Torres MC, Fadel MS, Bader D, Lutfi H, Kozonara ME. Robotic transfer of the latissimus dorsi associated with levator scapulae and rhomboid minor mini-open transfers for trapezium palsy. Arthrosc Techn. 2020;9(11):e1721–6.
Garcia JC Jr. Robotic transfer of the latissimus dorsi for irreparable Subscapularis tear. Arthrosc Techn. 2022;11(6):e1059–64.
Bozkurt M, Apaydin N, Işik Ç, Bilgetekin YG, Acar HI, Elhan AJTIJMR, Surgery CA. Robotic arthroscopic surgery: a new challenge in arthroscopic surgery part-I: robotic shoulder arthroscopy; a cadaveric feasibility study. Int J Med Robot Comput Assist Surg. 2011;7(4):496–500.
MacDermid JC, Bryant D, Holtby R, Razmjou H, Faber K, Balyk R, Boorman R, Sheps D, McCormack R. Arthroscopic versus mini-open rotator cuff repair: a randomized trial and meta-analysis. Am J Sports Med. 2021;49(12):3184–95.
Rashid MS, Arner JW, Millett PJ, Sugaya H, Emery R. The bankart repair: past, present, and future. J Shoulder Elb Surg. 2020;29(12):e491–8.
Crew B. Worth the cost? A closer look at the da Vinci robot’s impact on prostate cancer surgery. Nature. 2020;580(7804):5-S.
Chang EHE, Kim HY, Koh YW, Chung WY. Overview of robotic thyroidectomy. Gland Surg. 2017;6(3):218.
McDermott ER, Tennent DJ, Song DJ. Improving visualization in shoulder arthroscopy. Clin Shoulder Elb. 2023. https://doi.org/10.5397/cise.2022.01291.
Gerber C, Maquieira G, Espinosa N. Latissimus dorsi transfer for the treatment of irreparable rotator cuff tears. JBJS. 2006;88(1):113–20.
Ihara K, Katsube K, Misumi H, Kawai S. Successful restoration of the trapezius muscle using pedicle latissimus dorsi: a case report. Clin Orthop Relat Res. 2000;371:125–30.
Memon M, Kay J, Quick E, Simunovic N, Duong A, Henry P, Ayeni OR. Arthroscopic-assisted latissimus dorsi tendon transfer for massive rotator cuff tears: a systematic review. Orthop J Sports Med. 2018;6(6):2325967118777735.
Das S, Ganju A, Tiel RL, Kline DG. Tumors of the brachial plexus. NeuroSurg Focus. 2007;22(6):1–6.
Bertelli JA, Ghizoni MF. Results and current approach for brachial plexus reconstruction. J Brachial Plex Peripher Nerve Inj. 2011;6(01):e54–61.
Sinha S, Khani M, Mansoori N, Midha R. Adult brachial plexus injuries: surgical strategies and approaches. Neurol India. 2016;64(2):289.
Facca S, Hendriks S, Mantovani G, Selber JC, Liverneaux P. Robot-assisted surgery of the shoulder girdle and brachial plexus. In: Seminars in plastic surgery. New York: Thieme Medical Publishers; 2014. p. 039–44.
Oh WT, Kim SH, Koh IH, Koh YW, Choi YR. Robot-assisted retroauricular anterior scalenectomy for neurogenic thoracic outlet syndrome. Clin Orthop Surg. 2023;15(4):637–42.
Tetik C, Uzun M. Novel axillary approach for brachial plexus in robotic surgery: a cadaveric experiment. Minim Invasive Surg. 2014;2014: 927456.
Garcia JC Jr, Lebailly F, Mantovani G, Mendonca LA, Garcia J, Liverneaux P. Telerobotic manipulation of the brachial plexus. J Reconstr Microsurg. 2012;28(7):491–4.
Lee YM, Kim GW, Lee CY, Song E-K, Seon J-K. No difference in clinical outcomes and survivorship for robotic, navigational, and conventional primary total knee arthroplasty with a minimum follow-up of 10 years. Clin Orthop Surg. 2023;15(1):82–91.
Goh EZ, Ali T. Robotic surgery: an evolution in practice. J Surg Protocols Res Methodol. 2022;2022(1):snac003.
Wagner ER, Farley KX, Higgins I, Wilson JM, Daly CA, Gottschalk MB. The incidence of shoulder arthroplasty: rise and future projections compared with hip and knee arthroplasty. J Shoulder Elb Surg. 2020;29(12):2601–9.
Jassim SS, Benjamin-Laing H, Douglas SL, Haddad FS. Robotic and navigation systems in orthopaedic surgery: How much do our patients understand? Clin Orthop Surg. 2014;6(4):462–7.
Haikal ER, Fares MY, Abboud JA. Patient-specific implants in reverse shoulder arthroplasty. Clin Shoulder Elb. 2023. https://doi.org/10.5397/cise.2023.00038.
Rammohan R, Nugent L, Kasture S, Ganapathi M. Clinical outcomes after using patient specific instrumentation: is it worth the effort? A minimum 5-year retrospective review of 298 PSI knees. Arch Orthop Trauma Surg. 2022:1–14 .
Sassoon A, Nam D, Nunley R, Barrack R. Systematic review of patient-specific instrumentation in total knee arthroplasty: new but not improved. Clin Orthop Relat Res. 2015;473(1):151–8.
Gomes NS. Patient-specific instrumentation for total shoulder arthroplasty. EFORT Open Rev. 2016;1(5):177–82.
Bicknell RT, DeLude JA, Kedgley AE, Ferreira LM, Dunning CE, King GJ, Faber KJ, Johnson JA, Drosdowech DS. Early experience with computer-assisted shoulder hemiarthroplasty for fractures of the proximal humerus: development of a novel technique and an in vitro comparison with traditional methods. J Shoulder Elb Surg. 2007;16(3 Suppl):117–25.
Kircher J, Wiedemann M, Magosch P, Lichtenberg S, Habermeyer P. Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: a prospective-randomized clinical study. J Shoulder Elb Surg. 2009;18(4):515–20.
Barrett I, Ramakrishnan A, Cheung E. Safety and efficacy of intraoperative computer-navigated versus non-navigated shoulder arthroplasty at a tertiary referral. Orthop Clin. 2019;50(1):95–101.
Briem D, Ruecker AH, Neumann J, Gebauer M, Kendoff D, Gehrke T, Lehmann W, Schumacher U, Rueger JM, Grossterlinden LG. 3D fluoroscopic navigated reaming of the glenoid for total shoulder arthroplasty (TSA). Comput Aided Surg. 2011;16(2):93–9.
Verborgt O, De Smedt T, Vanhees M, Clockaerts S, Parizel PM, Van Glabbeek F. Accuracy of placement of the glenoid component in reversed shoulder arthroplasty with and without navigation. J Shoulder Elb Surg. 2011;20(1):21–6.
Venne G, Rasquinha BJ, Pichora D, Ellis RE, Bicknell R. Comparing conventional and computer-assisted surgery baseplate and screw placement in reverse shoulder arthroplasty. J Shoulder Elb Surg. 2015;24(7):1112–9.
Jackins S. Postoperative shoulder rehabilitation. Phys Med Rehabil Clin. 2004;15(3):643–82.
Kim B, Deshpande AD. An upper-body rehabilitation exoskeleton Harmony with an anatomical shoulder mechanism: design, modeling, control, and performance evaluation. Int J Robot Res. 2017;36(4):414–35.
Sicuri C, Porcellini G, Merolla G. Robotics in shoulder rehabilit
Comments (0)