Simultaneous multi-slice technique for reducing acquisition times in diffusion tensor imaging of the knee: a feasibility study

Oudeman J, Nederveen AJ, Strijkers GJ, Maas M, Luijten PR, Froeling M. Techniques and applications of skeletal muscle diffusion tensor imaging: a review. J Magn Reson Imaging. 2016;43(4):773–88.

Article  PubMed  Google Scholar 

Madry H, Kon E, Condello V, Peretti GM, Steinwachs M, Seil R, et al. Early osteoarthritis of the knee. Knee Surg Sports Traumatol Arthrosc. 2016;24(6):1753–62.

Article  PubMed  Google Scholar 

Chalian M, Roemer FW, Guermazi A. Advances in osteoarthritis imaging. Curr Opin Rheumatol. 2023;35(1):44–54.

Article  PubMed  Google Scholar 

Wang N, Mirando AJ, Cofer G, Qi Y, Hilton MJ, Johnson GA. Characterization complex collagen fiber architecture in knee joint using high-resolution diffusion imaging. Magn Reson Med. 2020;84(2):908–19.

Article  CAS  PubMed  PubMed Central  Google Scholar 

Liu S, Liu J, Chen W, Zhang L, Wu S, Wang F, et al. Diffusion tensor imaging for quantitative assessment of anterior cruciate ligament injury grades and graft. J Magn Reson Imaging. 2020;52(5):1475–84.

Article  PubMed  Google Scholar 

Liu S, Wan C, Li H, Chen W, Pan C. Diffusion tensor imaging of the lateral pterygoid muscle in patients with temporomandibular joint disorders and healthy volunteers. Korean J Radiol. 2022;23(2):218–25.

Article  PubMed  Google Scholar 

Raya JG, Melkus G, Adam-Neumair S, Dietrich O, Mutzel E, Reiser MF, et al. Diffusion-tensor imaging of human articular cartilage specimens with early signs of cartilage damage. Radiology. 2013;266(3):831–41.

Article  PubMed  Google Scholar 

Zhou X, Sakaie KE, Debbins JP, Narayanan S, Fox RJ, Lowe MJ. Scan-rescan repeatability and cross-scanner comparability of DTI metrics in healthy subjects in the SPRINT-MS multicenter trial. Magn Reson Imaging. 2018;53:105–11.

Article  PubMed  PubMed Central  Google Scholar 

Drake-Perez M, Boto J, Fitsiori A, Lovblad K, Vargas MI. Clinical applications of diffusion weighted imaging in neuroradiology. Insights Imaging. 2018;9(4):535–47.

Article  PubMed  PubMed Central  Google Scholar 

Fritz J, Fritz B, Zhang J, Thawait GK, Joshi DH, Pan L, et al. Simultaneous multislice accelerated turbo spin echo magnetic resonance imaging: comparison and combination with in-plane parallel imaging acceleration for high-resolution magnetic resonance imaging of the knee. Invest Radiol. 2017;52(9):529–37.

Article  CAS  PubMed  Google Scholar 

Gao F, Wen Z, Dou S, Kan X, Wei S, Ge Y. High-resolution simultaneous multi-slice accelerated turbo spin-echo musculoskeletal imaging: a head-to-head comparison with routine turbo spin-echo imaging. Front Physiol. 2021;12:759888.

Article  PubMed  PubMed Central  Google Scholar 

Filli L, Ghafoor S, Kenkel D, Liu W, Weiland E, Andreisek G, et al. Simultaneous multi-slice readout-segmented echo planar imaging for accelerated diffusion-weighted imaging of the breast. Eur J Radiol. 2016;85(1):274–8.

Article  PubMed  Google Scholar 

Lau AZ, Tunnicliffe EM, Frost R, Koopmans PJ, Tyler DJ, Robson MD. Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging. Magn Reson Med. 2015;73(3):995–1004.

Article  PubMed  Google Scholar 

Manoliu A, Ho M, Piccirelli M, Nanz D, Filli L, Dappa E, et al. Simultaneous multislice readout-segmented echo planar imaging for accelerated diffusion tensor imaging of the mandibular nerve: a feasibility study. J Magn Reson Imaging. 2017;46(3):663–77.

Article  PubMed  Google Scholar 

van den Borne MP, Raijmakers NJ, Vanlauwe J, Victor J, de Jong SN, Bellemans J, et al. International Cartilage Repair Society (ICRS) and Oswestry macroscopic cartilage evaluation scores validated for use in autologous chondrocyte implantation (ACI) and microfracture. Osteoarthr Cartil. 2007;15(12):1397–402.

Article  Google Scholar 

Steidle G, Schick F. Echoplanar diffusion tensor imaging of the lower leg musculature using eddy current nulled stimulated echo preparation. Magn Reson Med. 2010;55(3):541–8.

Article  Google Scholar 

Luca AD, Bertoldo A, Froeling M. Effects of perfusion on DTI and DKI estimates in the skeletal muscle. Magn Reson Med. 2017;78:233–46.

Zhao Q, Ridout RP, Shen J, Wang N. Effects of angular resolution and b value on diffusion tensor imaging in knee joint. Cartilage. 2021;13(2_suppl):295S-303S.

Article  PubMed  PubMed Central  Google Scholar 

Benali S, Johnston PR, Gholipour A, Dugan ME, Heberlein K, Bhat H, et al. Simultaneous multi-slice accelerated turbo spin echo of the knee in pediatric patients. Skelet Radiol. 2018;47(6):821–31.

Article  Google Scholar 

Koo TK, Li MY. A guideline of selecting and reporting intraclass correlation coefficients for reliability research. J Chiropr Med. 2016;15(2):155–63.

Article  PubMed  PubMed Central  Google Scholar 

Ohlmeyer S, Laun FB, Palm T, Janka R, Weiland E, Uder M, et al. Simultaneous multislice echo planar imaging for accelerated diffusion-weighted imaging of malignant and benign breast lesions. Invest Radiol. 2019;54(8):524–30.

Article  PubMed  Google Scholar 

Kenkel D, Barth BK, Piccirelli M, Filli L, Finkenstadt T, Reiner CS, et al. Simultaneous multislice diffusion-weighted imaging of the kidney: a systematic analysis of image quality. Invest Radiol. 2017;52(3):163–9.

Article  PubMed  Google Scholar 

Filli L, Piccirelli M, Kenkel D, Guggenberger R, Andreisek G, Beck T, et al. Simultaneous multislice echo planar imaging with blipped controlled aliasing in parallel imaging results in higher acceleration: a promising technique for accelerated diffusion tensor imaging of skeletal muscle. Invest Radiol. 2015;50(7):456–63.

Article  PubMed  Google Scholar 

Bernstein AS, Chen NK, Trouard TP. Bootstrap analysis of diffusion tensor and mean apparent propagator parameters derived from multiband diffusion MRI. Magn Reson Med. 2019;82(5):1796–803.

Article  PubMed  PubMed Central  Google Scholar 

Klupp E, Cervantes B, Schlaeger S, Inhuber S, Kreuzpointer F, Schwirtz A, et al. Paraspinal muscle DTI metrics predict muscle strength. J Magn Reson Imaging. 2019;50(3):816–23.

Article  PubMed  PubMed Central  Google Scholar 

Jones DK. The effect of gradient sampling schemes on measures derived from diffusion tensor MRI: a Monte Carlo study. Magn Reson Med. 2004;51(4):807–15.

Article  PubMed  Google Scholar 

Van Dyck P, Billiet T, Desbuquoit D, Verdonk P, Heusdens CH, Roelant E, et al. Diffusion tensor imaging of the anterior cruciate ligament graft following reconstruction: a longitudinal study. Eur Radiol. 2020;30(12):6673–84.

Article  PubMed  Google Scholar 

Ferizi U, Rossi I, Lee Y, Lendhey M, Teplensky J, Kennedy OD, et al. Diffusion tensor imaging of articular cartilage at 3T correlates with histology and biomechanics in a mechanical injury model. Magn Reson Med. 2017;78(1):69–78.

Article  CAS  PubMed  Google Scholar 

Lohmander LS, Atley LM, Pietka TA, Eyre DR. The release of crosslinked peptides from type II collagen into human synovial fluid is increased soon after joint injury and in osteoarthritis. Arthritis Rheum. 2003;48(11):3130–9.

Article  CAS  PubMed  Google Scholar 

Comments (0)

No login
gif