Feasibility and accuracy of continuous intraabdominal pressure monitoring with a capsular device in human pilot trial

Malbrain MLNG, Cheatham ML, Kirkpatrick A, Sugrue M, Parr M, De Waele J et al. Results from the International Conference of Experts on Intra-abdominal Hypertension and Abdominal Compartment Syndrome. I. Definitions. Intensive Care Med. 2006;32(11):1722–32.

Kušar M, Djokić M, Djordjević S, Hribernik M, Krašna S, Trotovšek B. Preliminary study of reliability of transcutaneous sensors in measuring intraabdominal pressure. Sci Rep. 2022;12(1):8268.

Article  PubMed  PubMed Central  Google Scholar 

Sanchez NC, Tenofsky PL, Dort JM, Shen LY. Others. What is normal intra-abdominal pressure?/Discussion. Am Surg. 2001;67(3):243.

Article  PubMed  CAS  Google Scholar 

Coccolini F, Biffl W, Catena F, Ceresoli M, Chiara O, Cimbanassi S, et al. The open abdomen, indications, management and definitive closure. World J Emerg Surg. 2015;10:32.

Article  PubMed  PubMed Central  Google Scholar 

De Keulenaer BL, De Waele JJ, Powell B, Malbrain MLNG. What is normal intra-abdominal pressure and how is it affected by positioning, body mass and positive end-expiratory pressure? Intensive Care Med. 2009;35(6):969–76.

Article  PubMed  Google Scholar 

Varela JE, Hinojosa M, Nguyen N. Correlations between intra-abdominal pressure and obesity-related co-morbidities. Surg Obes Relat Dis. 2009;5(5):524–8.

Article  PubMed  Google Scholar 

Niederauer S, Hunt G, Foreman KB, Merryweather A, Hitchcock R. Intrinsic factors contributing to elevated intra-abdominal pressure. Comput Methods Biomech Biomed Engin. 2023;26(8):941–51.

Article  PubMed  Google Scholar 

Cheatham ML, White MW, Sagraves SG, Johnson JL, Block EF. Abdominal perfusion pressure: a superior parameter in the assessment of intra-abdominal hypertension. J Trauma. 2000;49(4):621–6. discussion 626–7.

Article  PubMed  CAS  Google Scholar 

Diebel LN, Dulchavsky SA, Wilson RF. Effect of increased intra-abdominal pressure on mesenteric arterial and intestinal mucosal blood flow. J Trauma. 1992;33(1):45–8. discussion 48–9.

Article  PubMed  CAS  Google Scholar 

Malbrain MLNG, De Keulenaer BL, Khanna AK. Continuous intra-abdominal pressure: is it ready for prime time? Intensive Care Med. 2022;48(10):1501–4.

Article  PubMed  PubMed Central  Google Scholar 

Vidal MG, Ruiz Weisser J, Gonzalez F, Toro MA, Loudet C, Balasini C, et al. Incidence and clinical effects of intra-abdominal hypertension in critically ill patients. Crit Care Med. 2008;36(6):1823–31.

Article  PubMed  Google Scholar 

Balogh ZJ, van Wessem K, Yoshino O, Moore FA. Postinjury abdominal compartment syndrome: are we winning the battle? World J Surg. 2009;33(6):1134–41.

Article  PubMed  Google Scholar 

Kirkpatrick AW, Pelosi P, De Waele JJ, Malbrain ML, Ball CG, Meade MO, et al. Clinical review: intra-abdominal hypertension: does it influence the physiology of prone ventilation? Crit Care. 2010;14(4):232.

Article  PubMed  PubMed Central  Google Scholar 

Keskinen P, Leppaniemi A, Pettila V, Piilonen A, Kemppainen E, Hynninen M. Intra-abdominal pressure in severe acute pancreatitis. World J Emerg Surg. 2007;2:2.

Article  PubMed  PubMed Central  Google Scholar 

Raeburn CD, Moore EE, Biffl WL, Johnson JL, Meldrum DR, Offner PJ, et al. The abdominal compartment syndrome is a morbid complication of postinjury damage control surgery. Am J Surg. 2001;182(6):542–6.

Article  PubMed  CAS  Google Scholar 

McNelis J, Marini CP, Simms HH. Abdominal compartment syndrome: clinical manifestations and predictive factors. Curr Opin Crit Care. 2003;9(2):133–6.

Article  PubMed  Google Scholar 

Malbrain ML, Chiumello D, Cesana BM, Reintam Blaser A, Starkopf J, Sugrue M, et al. A systematic review and individual patient data meta-analysis on intra-abdominal hypertension in critically ill patients: the wake-up project. World initiative on abdominal hypertension epidemiology, a Unifying Project (WAKE-Up!). Minerva Anestesiol. 2014;80(3):293–306.

PubMed  CAS  Google Scholar 

Kuteesa J, Kituuka O, Namuguzi D, Ndikuno C, Kirunda S, Mukunya D, et al. Intra-abdominal hypertension; prevalence, incidence and outcomes in a low resource setting; a prospective observational study. World J Emerg Surg. 2015;10:57.

Article  PubMed  PubMed Central  Google Scholar 

Sugrue M, Jones F, Janjua KJ, Deane SA, Bristow P, Hillman K. Temporary abdominal closure: a prospective evaluation of its effects on renal and respiratory physiology. J Trauma. 1998;45(5):914–21.

Article  PubMed  CAS  Google Scholar 

Wise R, Rodseth R, Blaser A, Roberts D, De Waele J, Kirkpatrick A, et al. Awareness and knowledge of intra-abdominal hypertension and abdominal compartment syndrome: results of a repeat, international, cross-sectional survey. Anaesthesiol Intensive Ther. 2019;51(3):186–99.

Article  PubMed  Google Scholar 

Kimball EJ, Mone MC, Wolfe TR, Baraghoshi GK, Alder SC. Reproducibility of bladder pressure measurements in critically ill patients. Intensive Care Med. 2007;33(7):1195–8.

Article  PubMed  Google Scholar 

Cheatham ML, De Waele JJ, De Laet I, De Keulenaer B, Widder S, Kirkpatrick AW et al. The impact of body position on intra-abdominal pressure measurement: A multicenter analysis* [Internet]. Vol. 37, Critical Care Medicine. 2009. pp. 2187–90. https://doi.org/10.1097/ccm.0b013e3181a021fa

Kirkpatrick AW, Roberts DJ, De Waele J, Jaeschke R, Malbrain MLNG, De Keulenaer B, et al. Intra-abdominal hypertension and the abdominal compartment syndrome: updated consensus definitions and clinical practice guidelines from the World Society of the Abdominal Compartment Syndrome. Intensive Care Med. 2013;39(7):1190–206.

Article  PubMed  PubMed Central  Google Scholar 

Cummins G. Smart pills for gastrointestinal diagnostics and therapy. Adv Drug Deliv Rev. 2021;177:113931.

Article  PubMed  CAS  Google Scholar 

Cummins G, Cox BF, Ciuti G, Anbarasan T, Desmulliez MPY, Cochran S, et al. Gastrointestinal diagnosis using non-white light imaging capsule endoscopy. Nat Rev Gastroenterol Hepatol. 2019;16(7):429–47.

Article  PubMed  Google Scholar 

Mitrakos V, Cummins G, Tauber FJ, Cox BF, Pavuluri SK, Wood GS et al. PressureCap: An endoscopic sensor capsule for real-time gastrointestinal pressure monitoring. Device [Internet]. 2024 May 17 [cited 2024 Aug 22];2(5). https://www.cell.com/device/fulltext/S2666-9986(24)00117-0?uuid=uuid%3A292b681d-5085-49ca-85ab-7ca1e5b3f979

Abdigazy A, Arfan M, Lazzi G, Sideris C, Abramson A, Khan Y. End-to-end design of ingestible electronics. Nat Electron. 2024;7(2):102–18.

Article  Google Scholar 

Kuo B, Maneerattanaporn M, Lee AA, Baker JR, Wiener SM, Chey WD, et al. Generalized transit delay on wireless motility capsule testing in patients with clinical suspicion of gastroparesis, small intestinal dysmotility, or slow transit constipation. Dig Dis Sci. 2011;56(10):2928–38.

Article  PubMed  Google Scholar 

Stein E, Berger Z, Hutfless S, Shah L, Wilson LM, Haberl EB, et al. Wireless Motility Capsule Versus other Diagnostic technologies for evaluating Gastroparesis and constipation: a comparative effectiveness review. Rockville (MD): Agency for Healthcare Research and Quality (US); 2013.

Google Scholar 

Ho DR, Cheng CT, Ouyang CH, Lin WC, Liao CH. Validation of continuous intraabdominal pressure measurement: feasibility and accuracy assessment using a capsular device in in-vivo studies. World J Emerg Surg. 2024;19(1):25.

Article  PubMed  PubMed Central  Google Scholar 

Liao CH, Cheng CT, Chen CC, Jow UM, Chen CH, Lai YL et al. An Ingestible Electronics for Continuous and Real-Time Intraabdominal Pressure Monitoring. J Pers Med [Internet]. 2020;11(1). https://doi.org/10.3390/jpm11010012

Cao Q, Deng R, Pan Y, Liu R, Chen Y, Gong G, et al. Robotic wireless capsule endoscopy: recent advances and upcoming technologies. Nat Commun. 2024;15(1):4597.

Article  PubMed  PubMed Central  CAS  Google Scholar 

Koo TK, Li MY. A Guideline of selecting and reporting Intraclass correlation coefficients for Reliability Research. J Chiropr Med. 2016;15(2):155–63.

Article  PubMed  PubMed Central  Google Scholar 

Walter SD, Eliasziw M, Donner A. Sample size and optimal designs for reliability studies. Stat Med. 1998;17(1):101–10.

Article  PubMed  CAS  Google Scholar 

Kyoung KH, Hong SK. The duration of intra-abdominal hypertension strongly predicts outcomes for the critically ill surgical patients: a prospective observational study. World J Emerg Surg. 2015;10(1):22.

Article  PubMed  PubMed Central 

Comments (0)

No login