Background and objectives Continuous full-channel EEG is the gold standard for electrocortical activity assessment in critically ill children, but its implementation faces challenges, leading to a growing use of amplitude-integrated EEG (aEEG). While suppressed aEEG amplitudes have been linked to adverse outcomes in preterm infants and adults after cardiac arrest, evidence for critically ill children remains limited. This retrospective study aimed to evaluate the association between suppressed aEEG amplitudes in critically ill children and death or poor functional neurological outcomes.
Methods 235 EEGs derived from individual patients < 18 years in the pediatric intensive care unit (PICU) at the University Hospital Essen (Germany) between 04/2014 and 07/2021 were retrospectively converted into aEEGs and amplitudes analyzed with respect to previously defined age-specific percentiles. Adjusted odds ratios for death and poor functional outcome at hospital discharge in patients with bilateral upper or lower amplitude suppression below the 10th percentile were calculated accounting for neurological injuries, acute disease severity, sedation levels, and functional neurological status before acute critical illness.
Results The median time from neurological insult to EEG recording was 2 days. PICU admission occurred due to neurological reasons in 43 % and patients had high overall disease severity. Thirty-three (14 %) patients died and 68 (29 %) had poor outcomes. Amplitude depression below the 10th percentile was frequent (upper amplitude: 27 %, lower amplitude: 34 %) with suppression of only one amplitude less frequent than bilateral suppression. Multivariable regression analyses yielded odds between 6.63 and 15.22 for death, neurological death, and poor neurological outcomes if both upper or both lower amplitudes were suppressed. Model discrimination was excellent with areas under the curve above 0.92 for all models.
Discussion This study found a high prevalence of suppressed aEEG amplitudes in critically ill children early after PICU admission, with suppression being highly associated with death and poor functional outcomes at hospital discharge. These findings emphasize the potential of early identification of high-risk PICU patients through aEEG monitoring if conventional EEG is unavailable, potentially guiding neuroprotective therapies and early neurorehabilitation.
Competing Interest StatementThe authors have declared no competing interest.
Funding StatementThis study did not receive any funding
Author DeclarationsI confirm all relevant ethical guidelines have been followed, and any necessary IRB and/or ethics committee approvals have been obtained.
Yes
The details of the IRB/oversight body that provided approval or exemption for the research described are given below:
The study was approved by the local Ethics Committee of the Medical Faculty of the University of Duisburg-Essen (21-10264-BO). Written informed consent was waived according to local legislation for analysis of retrospective anonymized data.
I confirm that all necessary patient/participant consent has been obtained and the appropriate institutional forms have been archived, and that any patient/participant/sample identifiers included were not known to anyone (e.g., hospital staff, patients or participants themselves) outside the research group so cannot be used to identify individuals.
Yes
I understand that all clinical trials and any other prospective interventional studies must be registered with an ICMJE-approved registry, such as ClinicalTrials.gov. I confirm that any such study reported in the manuscript has been registered and the trial registration ID is provided (note: if posting a prospective study registered retrospectively, please provide a statement in the trial ID field explaining why the study was not registered in advance).
Yes
I have followed all appropriate research reporting guidelines, such as any relevant EQUATOR Network research reporting checklist(s) and other pertinent material, if applicable.
Yes
Comments (0)