Liu F, Hernandez-Cabronero M, Sanchez V, Marcellin MW, Bilgin A: The Current Role of Image Compression Standards in Medical Imaging. In: Information. vol. 8; 2017.
Ringl H, Schernthaner R, Sala E, El-Rabadi K, Weber M, Schima W, Herold CJ, Dixon AK: Lossy 3D JPEG2000 Compression of Abdominal CT Images in Patients with Acute Abdominal Complaints: Effect of Compression Ratio on Diagnostic Confidence and Accuracy. Radiology 2008, 248(2):476-484.
Savcenko V, Erickson BJ, Persons KR, Campeau NG, Huston J, Wood CP, Schreiner SA: An evaluation of JPEG and JPEG 2000 irreversible compression algorithms applied to neurologic computed tomography and magnetic resonance images. Journal of Digital Imaging 2000, 13(1):183-185.
Article CAS PubMed PubMed Central Google Scholar
Sung M-M, Kim H-J, Yoo SK, Choi B-W, Nam J-E, Kim H-S, Lee J-H, Yoo H-S: Clinical Evaluation of Compression Ratios using JPEG2000 on Computed Radiography Chest Images. Journal of Digital Imaging 2002, 15(2):78-83.
Article PubMed PubMed Central Google Scholar
Wallace GK: The JPEG still picture compression standard. Commun ACM 1991, 34(4):30–44.
Fischer M, Neher P, Schüffler P, Ziegler S, Xiao S, Peretzke R, Clunie D, Ulrich C, Baumgartner M, Muckenhuber A et al: Unlocking the potential of digital pathology: Novel baselines for compression. Journal of Pathology Informatics 2025, 17:100421.
Article PubMed PubMed Central Google Scholar
Jason K, Marc de K, Alexander W, Darren T: Digital pathology whole slide image compression with vector quantized variational autoencoders. In: ProcSPIE: 2023; 2023: 124711B.
Krupinski EA, Johnson JP, Jaw S, Graham AR, Weinstein RS: Compressing pathology whole-slide images using a human and model observer evaluation. Journal of Pathology Informatics 2012, 3(1):17.
Article PubMed PubMed Central Google Scholar
Han B, Zheng R, Zeng H, Wang S, Sun K, Chen R, Li L, Wei W, He J: Cancer incidence and mortality in China, 2022. Journal of the National Cancer Center 2024, 4(1):47-53.
Article PubMed PubMed Central Google Scholar
Kim J, Harper A, McCormack V, Sung H, Houssami N, Morgan E, Mutebi M, Garvey G, Soerjomataram I, Fidler-Benaoudia MM: Global patterns and trends in breast cancer incidence and mortality across 185 countries. Nature Medicine 2025, 31(4):1154-1162.
Article CAS PubMed Google Scholar
Marcellin MW, Gormish MJ, Bilgin A, Boliek MP: An overview of JPEG-2000. In: Proceedings DCC 2000 Data Compression Conference: 28–30 March 2000 2000; 2000: 523–541.
Bruylants T, Schelkens P, Tzannes A: JP3D – Extensions for Three-Dimensional Data (Part 10). In: The JPEG 2000 Suite. edn.; 2009: 199–227.
Sullivan GJ, Ohm JR, Han WJ, Wiegand T: Overview of the High Efficiency Video Coding (HEVC) Standard. IEEE Transactions on Circuits and Systems for Video Technology 2012, 22(12):1649-1668.
Boopathiraja S, Punitha V, Kalavathi P, Prasath VBS: Computational 2D and 3D Medical Image Data Compression Models. Archives of Computational Methods in Engineering 2022, 29(2):975-1007.
Article CAS PubMed Google Scholar
Bourai NEH, Merouani HF, Djebbar A: Deep learning-assisted medical image compression challenges and opportunities: systematic review. Neural Computing and Applications 2024, 36(17):10067-10108.
Urbaniak IA: Using Compressed JPEG and JPEG2000 Medical Images in Deep Learning: A Review. Applied Sciences 2024, 14(22):10524.
Li Z, Ramos A, Li Z, Osborn ML, Zaid W, Li X, Li Y, Xu J: Nearly-lossless-to-lossy medical image compression by the optimized JPEGXT and JPEG algorithms through the anatomical regions of interest. Biomedical Signal Processing and Control 2023, 83:104711.
Ringl H, Schernthaner RE, Kulinna-Cosentini C, Weber M, Schaefer-Prokop C, Herold CJ, Schima W: Lossy Three-dimensional JPEG2000 Compression of Abdominal CT Images: Assessment of the Visually Lossless Threshold and Effect of Compression Ratio on Image Quality. Radiology 2007, 245(2):467-474.
Mantiuk RK, Tomaszewska A, Mantiuk R: Comparison of Four Subjective Methods for Image Quality Assessment. 2012, 31(8):2478-2491.
Afnan, Ullah F, Yaseen, Lee J, Jamil S, Kwon O-J: Subjective Assessment of Objective Image Quality Metrics Range Guaranteeing Visually Lossless Compression. 2023, 23(3):1297.
Hoeijmakers EJI, Martens B, Hendriks BMF, Mihl C, Miclea RL, Backes WH, Wildberger JE, Zijta FM, Gietema HA, Nelemans PJ et al: How subjective CT image quality assessment becomes surprisingly reliable: pairwise comparisons instead of Likert scale. European Radiology 2024, 34(7):4494-4503.
Article PubMed PubMed Central Google Scholar
DeLong ER, DeLong DM, Clarke-Pearson DL: Comparing the areas under two or more correlated receiver operating characteristic curves: a nonparametric approach. Biometrics 1988, 44(3):837-845.
Article CAS PubMed Google Scholar
Haynes W: Benjamini–Hochberg Method. In: Encyclopedia of Systems Biology. edn. Edited by Dubitzky W, Wolkenhauer O, Cho K-H, Yokota H. New York, NY: Springer New York; 2013: 78–78.
Lee KH, Kim YH, Kim BH, Kim KJ, Kim TJ, Kim HJ, Hahn S: Irreversible JPEG 2000 compression of abdominal CT for primary interpretation: assessment of visually lossless threshold. European Radiology 2007, 17(6):1529-1534.
Pole A, Shriram R: 3-D Medical Image Compression by Using HEVC. In: 2018 Fourth International Conference on Computing Communication Control and Automation (ICCUBEA): 16–18 Aug. 2018 2018; 2018: 1–5.
Xue D, Ma H, Li L, Liu D, Xiong Z: aiWave: Volumetric Image Compression With 3-D Trained Affine Wavelet-Like Transform. IEEE Transactions on Medical Imaging 2023, 42(3):606-618.
Bruylants T, Munteanu A, Alecu A, Deklerck R, Schelkens P: Volumetric image compression with JPEG2000. In: SPIE the international society for optical engineering: 2007; 2007: 1–2.
Xue D, Li L, Liu D, Li H: Lightweight Context Model Equipped aiWave in Response to the AVS Call for Evidence on Volumetric Medical Image Coding. IEEE Transactions on Circuits and Systems for Video Technology 2024, 34(5):3125-3137.
Li S, Lu J, Hu Y, Mattos LS, Li Z: Towards scalable medical image compression using hybrid model analysis. Journal of Big Data 2025, 12(1):45.
Comments (0)