Neutral Zone vs. Conventional Denture Fabrication: A Randomized Crossover Study on Denture Performance

 

Karthik Kannaiyan, Department of Prosthodontics, Faculty of Dentistry, Manipal University College Malaysia, Melaka, MalaysiaFollow
Arunima Chauhan, Department of Oral Pathology, Faculty of Dentistry, Manipal University College Malaysia, Melaka, MalaysiaFollow
Vijayendranath Nayak, Department of Oral Medicine and Radiology, Faculty of Dentistry, Manipal University College Malaysia, Melaka, MalaysiaFollow
Riyshmaa Devendaran, Faculty of Dentistry, Manipal University College Malaysia, Melaka, Malaysia
Dashmita Peterson, Faculty of Dentistry, Manipal University College Malaysia, Melaka, Malaysia
Pavittra Kanesan, Faculty of Dentistry, Manipal University College Malaysia, Melaka, Malaysia
Vityaa Lakshmi, Faculty of Dentistry, Manipal University College Malaysia, Melaka, Malaysia

Abstract

Objectives: It is challenging to achieve satisfactory outcomes in a complete denture for patients with resorbed residual ridges. Utilization of neutral zone techniques to guide posterior denture tooth arrangement and denture base contouring has been considered for many decades. However, the evidence is still not enough to revise protocols. This study aimed to compare patient satisfaction and stability of neutral zone denture with conventional denture. Methods: A crossover clinical trial was conducted among patients with resorbed mandibular ridges. Each participant received two sets of dentures: one fabricated using the neutral zone technique and one using the conventional method, in a randomized sequence. Denture stability was assessed clinically at the time of insertion. Patient satisfaction was recorded after three weeks of wearing each denture using a structured questionnaire. Data were analyzed using paired t-tests for within-subject comparisons, and carryover effects were evaluated using pre-test. Results: The carry-over effect was not statistically significant for both satisfaction (p = 0.099) and stability (p = 0.316). The stability of neutral zone denture was significantly higher than conventional denture (p = 0.043). Conclusion: Dentures prepared using neutral zone technique have been found to be more stable when compared to ones prepared using conventional methods.

References Raja HZ, Saleem MN. Neutral zone dentures versus conventional dentures in diverse edentulous periods. Biomedica. 2009;2 5:136–45. Nanda A, Kaur H, Koli D, Verma M. A simplified technique to record neutral zone and cameo surface in complete denture. Indian J Dent Res. 2024; 35(1):95–7. Cagna DR, Massad JJ, Schiesser FJ. The neutral zone revisited: From historical concepts to modern application. J Prosthet Dent. 2009; 101(6):405–12. Mustafa AZ. Effect of the lingual ledge of neutral zone impression on the retention and stability of mandibular complete denture in elders with atrophied alveolar ridge. Tanta Dent J. 2015; 12(2):111–8. Geerts GAVM. Neutral zone or conventional mandibular complete dentures: a randomised crossover trial comparing oral health-related quality of life. J Oral Rehabil. 2017; 44(9):702–8. Ladha K, Gupta R, Gill S, Verma M. Patient satisfaction with complete dentures fabricated using two neutral zone techniques: a within-subject cross-over pilot study. J Indian Prosthodont Soc. 2014;14(2):161–8. Al-Magaleh WR, Swelem AA, Abdelnabi MH, Mofadhal A. Effect on patient satisfaction of mandibular denture tooth arrangement in the neutral zone. J Prosthet Dent. 2019; 121(3):440–446. Elmoula HA, Khalifa N, Alhajj MN. Comparison between masticatory index and mixing index among complete denture wearers and associated factors: A multivariate analysis. J Prosthet Dent. 2018; 120(1):35–42. Limpuangthip N, Techapiroontong S, Prawatvatchara W. A systematic review of patient-oriented outcomes following complete denture treatment: a comparison between the neutral zone technique and conventional approach. BDJ Open. 2024; 10(1):37. Porwal A, Sasaki K. Current status of the neutral zone: A literature review. J Prosthet Dent. 2013; 109(2):129–34. Wellek S, Blettner M. On the proper use of the crossover design in clinical trials: Part 18 of a series on evaluation of scientific publications. Dtsch Arztebl Int. 2012; 109(15):276–81. Lo Russo L, Guida L, Ronsivalle V, Ercoli C. Digital denture with mucostatic base and functional borders: A cast-free digital technique. J Prosthodont. 2024. Tomar SS, Rathee M, Diwan K, Senthilvelpalani B. Unconventional digital dentures: Overcoming software challenges and integrating digital workflows into conventional techniques. J Prosthet Dent. 2024; 132(6):1103.e1–8. Ladha K, Gupta R, Gill S, Verma M. Patient satisfaction with complete dentures fabricated using two neutral zone techniques: A within-subject cross-over pilot study. J Indian Prosthodont Soc. 2014; 14(2):161–8. Mobbs RJ. From the subjective to the objective era of outcomes analysis: How the tools we use to measure outcomes must change to be reflective of the pathologies we treat in spinal surgery. J Spine Surg. 2021; 7(3):456–7. Kluzek S, Dean B, Wartolowska KA. Patient-reported outcome measures (PROMs) as proof of treatment efficacy. BMJ Evid Based Med. 2022; 27(3):153–5. Recommended Citation

Kannaiyan, K., Chauhan, A., Nayak, V., Devendaran, R., Peterson, D., Kanesan, P., & Lakshmi, V. Neutral Zone vs. Conventional Denture Fabrication: A Randomized Crossover Study on Denture Performance. J Dent Indones. 2025;32(2): 115-119

COinS

 

 

 

 

Comments (0)

No login
gif