Palak Ravjibhai Ranparia, Department of Conservative Dentistry and Endodontics, Karnavati School of Dentistry, Gujarat, IndiaFollow
Chintan Joshi, Department of Conservative Dentistry and Endodontics, Karnavati School of Dentistry, Gujarat, IndiaFollow
Mona Somani, Department of Conservative Dentistry and Endodontics, Karnavati School of Dentistry, Gujarat, IndiaFollow
Aashray Patel, Department of Conservative Dentistry and Endodontics, Karnavati School of Dentistry, Gujarat, IndiaFollow
Urooj Desai, Department of Conservative Dentistry and Endodontics, Karnavati School of Dentistry, Gujarat, IndiaFollow
Janki Prajapati, Department of Conservative Dentistry and Endodontics, Karnavati School of Dentistry, Gujarat, IndiaFollow
Objective: In this work, Hyflex CM, TruNatomy, and Plex V heat-treated nickel titanium rotary instruments were evaluated at body temperature (36 °C ± 1 °C) with and without a cooling protocol to assess the cyclic fatigue resistance. Methods: A 90° curved stainless-steel block was used for cyclic fatigue tests on 60 randomly selected rotary instruments, divided into two groups of 30: body temperature (n = 10) and body temperature with cooling (n = 10). Instruments were further subdivided into 6 groups of 3 different instruments. Cooling protocol group instruments received 5-second spray cooling every 30 seconds, along with continuous 5% sodium hypochlorite. Instrument fractures were recorded via audiovisual methods, inspected under a stereomicroscope, and statistically analyzed. Results: Significant cyclic fatigue resistance was observed in both body temperature and cooling protocol groups in intergroup and intragroup comparisons. Plex V files outperformed others at body temperature, while TruNatomy showed superior cyclic fatigue resistance in the cooling protocol group. Each group displayed expected signs of cyclic fatigue behavior under the stereomicroscope. Conclusion: All three instruments showed comparable cyclic fatigue resistance at body temperature, and the cooling treatment enhanced their resistance. TruNatomy presents a better outcome than other tested files after the cooling protocol.
References Furlan RD, Alcalde MP, Duarte MAH, Bramante CM, Piasecki L, Vivan RR. Cyclic and torsional fatigue resistance of seven rotary systems. Iran Endod J. 2021;16(2):78–84. Yazdizadeh M, Skini M, Hoseini Goosheh SM, Jafarzadeh M, Shamohammadi M, Rakhshan V. Effect of deep cryogenic treatment on cyclic fatigue of endodontic rotary nickel titanium instruments. Iran Endod J. 2017 ;12(2):216–9. Ferreira F, Adeodato C, Barbosa I, Aboud L, Scelza P, Zaccaro Scelza M. Movement kinematics and cyclic fatigue of NiTi rotary instruments: A systematic review. Int Endod J. 2017; 50(2):143–52. Kaval ME, Capar ID, Ertas H, Sen BH. Comparative evaluation of cyclic fatigue resistance of four different nickel-titanium rotary files with different cross-sectional designs and alloy properties. Clin Oral Investig. 2017; 21(5):1527–30. Zhou H, Peng B, Zheng YF. An overview of the mechanical properties of nickel–titanium endodontic instruments. Endod Topics. 2013; 29(1):42–54. Pirani C, Iacono F, Generali L, Sassatelli P, Nucci C, Lusvarghi L, Gandolfi M, Prati C. HyFlex EDM: Superficial features, metallurgical analysis and fatigue resistance of innovative electro discharge machined NiTi rotary instruments. Int Endod J. 2016; 49(5):483–93. Shen Y, Zhou HM, Zheng YF, Peng B, Haapasalo M. Current challenges and concepts of the thermomechanical treatment of nickel-titanium instruments. J Endod. 2013; 39(2):163–72. Grande NM, Plotino G, Silla E, Pedulla E, DeDeus G, Gambarini G, Somma F. Environmental temperature drastically affects flexural fatigue resistance of nickel-titanium rotary files. J Endod. 2017: 43(7):1157–60. Jamleh A, Yahata Y, Ebihara A, Atmeh AR, Bakhsh T, Suda H. Performance of NiTi endodontic instrument under different temperatures. Odontology. 2016; 104(3):324–8. Dosanjh A, Paurazas S, Askar M. The effect of temperature on cyclic fatigue of nickel-titanium rotary endodontic instruments. J Endod. 2017; 43(5):823–6. Meling TR, Odegaard J. Short-term temperature changes influence the force exerted by superelastic nickel-titanium archwires activated in orthodontic bending. Am J Orthod Dentofacial Orthop. 1998; 114(5):503–9. Cai C, Chen X, Li Y, Jiang Q. Advances in the role of sodium hypochlorite irrigant in chemical preparation of root canal treatment. Biomed Res Int. 2023; 2023:8858283. Zupanc J, Vahdat-Pajouh N. Schafer E. New thermomechanically treated NiTi alloys - a review. Int Endod J. 2018; 51(10):1088–103. Plotino G, Grande NM, Mercadé Bellido M, Testarelli L, Gambarini G. Influence of temperature on cyclic fatigue resistance of ProTaper Gold and ProTaper Universal Rotary Files. J Endod. 2017; 43(2):200–2. de Morais CA, Bernardinelli N, Lima WM, Cupertino RR, Guerisoli DM. Evaluation of the temperature of different refrigerant sprays used as a pulpal test. Aust Endod J. 2008; 34(3):86–8. Klymus ME, Alcalde MP, Vivan RR, Só MVR, de Vasconselos BC, Duarte MAH. Effect of temperature on the cyclic fatigue resistance of thermally treated reciprocating instruments. Clin Oral Investig. 2019; 23(7):3047–52. Plotino G, Grande NM, Testarelli L, Gambarini G, Castagnola R, Rossetti A, Özyürek T, Cordaro M, Fortunato L. Cyclic fatigue of reciproc and reciproc blue nickel-titanium reciprocating files at different environmental temperatures. J Endod. 2018; 44(10):1549–52. Sakkir N, Thaha KA, Nair MG, Joseph S, Christalin R. Management of dilacerated and s-shaped root canals an endodontist's challenge. J Clin Diagn Res. 2014; 8(6):ZD22–4. Burroughs JR, Bergeron BE, Roberts MD, Hagan JL, Himel VT. Shaping ability of three nickel-titanium endodontic file systems in simulated S-shaped root canals. J Endod. 2012; 38(12):1618–21. Inan U, Keskin C, Sivas Yilmaz Ö, Baş G. Cyclic fatigue of Reciproc Blue and Reciproc instruments exposed to intracanal temperature in simulated severe apical curvature. Clin Oral Investig. 2019; 23(5):2077–82. Keskin C, Inan U, Demiral M, Keleş A. Cyclic Fatigue Resistance of Reciproc Blue, Reciproc, and WaveOne Gold Reciprocating Instruments. J Endod. 2017; 43(8):1360–3. Riyahi AM, Bashiri A, Alshahrani K, Alshahrani S, Alamri HM, Al-Sudani D. Cyclic Fatigue Comparison of TruNatomy, Twisted File, and ProTaper Next Rotary Systems. Int J Dent. 2020; 2020:3190938. Tanomaru-Filho M, Galletti Espir C, Carolina Venção A, Macedo-Serrano N, Camilo-Pinto J, Guerreiro-Tanomaru J. Cyclic fatigue resistance of heat-treated nickel-titanium instruments. Iran Endod J. 2018; 13(3):312–7. Li UM, Lee BS, Shih CT, Lan WH, Lin CP. Cyclic fatigue of endodontic nickel titanium rotary instruments: Static and dynamic tests. J Endod. 2002; 28(6):448–51. AbuMostafa A, Alfadaghem M. Influence of short-term cooling on the performance of superelastic and thermally-treated rotary NiTi files tested in dynamic cyclic fatigue model. Front Biosci (Landmark Ed). 2021; 26(12):1464–9. Recommended CitationRanparia, P. R., Joshi, C., Somani, M., Patel, A., Desai, U., & Prajapati, J. Cooling Protocols Impact on Nickel-Titanium Rotary Instruments Cyclic Fatigue Resistance Under Extreme Curvatures and Sodium Hypochlorite. J Dent Indones. 2025;32(2): 120-126
DOWNLOADS
Since August 30, 2025
COinS
Comments (0)